  http://www.tracopower.com page 1 of 5 industrial power supplies tcl series, 24C120 watt features for industrial, of?ce and residential application ultracompact plastic housing connection by cage clamps terminals or plugable screw terminals reliable snap-on mounting on din-rails adaptor for wall mounting universal input 85-264 vac, 50/60 hz models with 5, 12, 24 and 48 vdc output output voltage adjustable power good signal low ripple and noise overload and short-circuit protection parallel operation possible worldwide safety approvals redundancy module 3 year product warranty the tracopower tcl series are a family of din-rail power supplies with an ex - cellent price/performance ratio. with tightly regulated output voltage and high im - munity against electrical disturbances on the mains they provide a reliable power source for sensitive loads in industrial process controls, machine tools and other equipment exposed to a dif?cult industrial environment. compact size, light weight, easy snap-on mounting on din-rails and the choice of two connection terminal versions are other features of these power supplies. the tcl series complies with all mayor safety standards for europe (en60950, en50178), north america (ul/ cul60950, ul508c listed) or elsewhere in the world (with cb-report iec60950). ordercode input voltage output power *output voltage output current connection range max. nom. max. tcl 024-105 5.1 vdc 4.0 a tcl 024-112 24 w 12 vdc 2.0 a tcl 024C124 24 vdc 1.0 a tcl 060C112 12 vdc 4.0 a detachable screw tcl 060C124 60 w 24 vdc 2.5 a terminal block tcl 060C148 85 C264 vac 48 vdc 1.25 a tcl 120C112 universal input 120 w 12 vdc 8.0 a tcl 120C124 50 / 60 hz 24 vdc 5.0 a tcl 024C124c 24 w 24 vdc 1.0 a tcl 060C112c 12 vdc 4.0 a tcl 060C124c 60 w 24 vdc 2.5 a cage-clamps tcl 060C148c 48 vdc 1.25 a tcl 120C112c 120 w 12 vdc 8.0 a tcl 120C124c 24 vdc 5.0 a models ul 60950 ul 508c *output adjustable ne w
http://www.tracopower.com page 2 of 5 all speci?cations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated. industrial power supplies tcl series 24 C120 watt input specifications input voltage range 85...264 vac / 85...375 vdc output derating at operation between 85...93vac/85...130vdc: 15% for tcl 060 & tcl 120 models 20% for tcl 024-112 & tcl 024-124 30% for tcl 024-105 input frequency 47 C 63 hz harmonic limits en610000-3-2 class a input current at full load (typ.) 115 vac 230 vac tcl 24 models: 0.35 a 0.2 a tcl 60 models: 1.2 a 0.6 a tcl 120 models: 2.0 a 1.0 a recommended circuit breaker (characteristic c or slow blow fuse) 5.0 a output specifications output voltage adj. range 5.1 vdc model: 5.0 C 5.25 vdc (pot.meter on frontpanel) 12 vdc models: 12 C 15 vdc (12 - 16 vdc for tcl 024-112) 24 vdc models: 24 C 28 vdc 48 vdc models: 48 C 56 vdc output regulation (10 to 90% load variation) 2.5% (1% for tcl 60-112) ripple and noise (20mhz bandwidth) < 50 mv pk-pk electronic short circuit protection current limitation at 120 % typ (constant current, automatic recovery tcl 24 models: foldback, automatic recovery) parallel operation output current characteristic suitable for parallel operation of max. 5 units overvoltage protection, triggerpoint 5.1 vdc model: < 6.5 vdc 12 / 24 vdc models: < 40 vdc 48 vdc models: < 60 vdc hold-up time 115 vac 230 vac min. 15 ms min. 125 ms power good signal (tcl 60 & tcl 120 only) trigger output signal point (reference to C vout) 12 vdc models: >11v 11.0 v 1.0v / 60 ma max. 24 vdc models: >22v 22.0 v 2.0v / 30 ma max. 48 vdc models: >44v 44.0 v 4.0v / 15 ma max. general specifications temperature ranges C operating C 10 c+70 c max. C storage (non operating) C 25 c+85 c temperature derating C at 187...264 vac or 265...375 vdc operation 1.7% /k above 50c C at 93...132 vac or 130...187 vdc operation 1.1% /k above 40c C at 85...130 vdc operation 1.3% /k above 30c humidity (non condensing) 95 % rel. h max. temperature coefficient 0.02 % /k switching frequency 55 C 180 khz depending on load (frequency modulation) efficiency 88% typ. isolation according to iec/en 60950, ul 60950, ul 508, en 50178, en 60204, en 61558-2-8 reliability, calculated mtbf @ 25c tcl 24 models: >2.68 mio h (according to iec-1709) tcl 60 models: >2.94 mio h tcl 120 models: >1.62 mio h
http://www.tracopower.com page 3 of 5 all speci?cations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated. general specifications safety standards iec 60950, en 60950 (output selv), ul 60950, ul 508, en 50178, en 60204, en 61558-2-8. - nec class 2 (tcl 60 models only) safety approvals (tcl 24 models pending) ul/cul 60950 recognized, file e181381 ul 508c listed, file e210002 cb-report per iec 60950 electromagnetic compatibility (emc), emissions en 61000-6-3 electromagnetic compatibility (emc), immunity en 61000-6-2 safety class degree of protection class 1 case protection ip 20 (iec 60529) enclosure material plastic fr2010-110c (ul 94v-0 rated) mounting 35 mm din-rails as per en 50022-35x15/7.5 (snap-on with self-locking spring) adapter for wall-/chassi mounting (included) options output characteristic optimized for battery charging available on request industrial power supplies tcl series 24 C120 watt tclCrem240 redundancy module this module enables redundant operation of any two tcl models by decoupling the 2 power supplies. it can also be used to separate sensitive loads from the main power source. order code inputs vin max power per input output voltage output current max. connection tclCrem240 2 x 5...60 vdc 144 w vin C 0.9 vdc 8 a detachable screw terminal block models specifications operating temperature C 10c...+70c max. (14f...+158f) derating above 40c (104f): 1.5%/k electromagnetic compatibility in correspondence to connected units (no internal switching device) dimensions same as model tcl 24 (see page 4)
http://www.tracopower.com page 4 of 5 all speci?cations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated. 27 (1.06) 2.2 (0.09) 100.0 (3.94) 75.0 (2.95) dc-on led output voltage adjust input 1 2 3 output 1 2 outline dimensions mm (inches) industrial power supplies tcl series 24 C120 watt tcl 24 and tcl-rem240 tcl 60 weight: 140g (4.9 oz) weight: 265g (9.4 oz) output innput 1 +vout 1 ac ground 2 Cvout 2 neutral 3 live output innput 1 +vout 1 ac ground 2 +vout 2 neutral 3 Cvout 3 live 4 Cvout 5 power good 75.0 (2.95) 100.0 (3.94) 3.2 (0.13) 45 (1.77) dc-on led output voltage adjust output 1 2 3 4 5 input 1 2 3 tolerances: 0.5mm (0.02)
page 5 of 5 speci?cations can be changed without notice outline dimensions mm (inches) j enatschstrasse 1 ch-8002 zurich switzerland t el. +41 43311 4511 fax +41 43311 4545 info@traco.ch www .tracopower .com industrial power supplies tcl series 24 C120 watt tcl 120 weight: 440g (15.5 oz) output innput 1 +vout 1 ac ground 2 +vout 2 neutral 3 Cvout 3 live 4 Cvout 5 power good tolerances: 0.5mm (0.02) wall mounting bracket instead on a din-rail, the module can be easily mounted on a chassis or wall with help of a mounting bracket which is supplied as standard with each power supply 75.0 (2.95) 100.0 (3.94) 3.2 (0.13) 85 (3.35) dc-on led output voltage adjust output 1 2 3 4 5 input 1 2 3 din rail mounting hooks 20mm (0.79) wide rev. 07/05


▲Up To Search▲   

 
Price & Availability of TCL120-124C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X